Welcome to the Lochinvar Noble Combi Boiler Manual, a comprehensive guide for installers and service technicians․ This manual provides essential information for installation, operation, and maintenance of the Noble Combi Boiler, ensuring safe and efficient performance․ Designed for qualified professionals, it outlines key steps and best practices to optimize boiler functionality and longevity․
1․1 Overview of the Noble Combi Boiler
The Lochinvar Noble Combi Boiler is a high-efficiency, condensing gas boiler designed for residential applications․ It combines space heating and domestic hot water production in one compact unit․ Featuring a 10:1 turndown ratio and 95% AFUE, this boiler ensures reliable performance and energy savings․ Its advanced fire tube heat exchanger design enhances durability and heat transfer efficiency․ Engineered and assembled in the USA, the Noble Combi Boiler offers a versatile solution for modern heating needs, with easy installation and service capabilities․
1․2 Importance of the Manual for Installation and Service
The Lochinvar Noble Combi Boiler Manual is crucial for proper installation, operation, and maintenance․ It provides detailed instructions for installers and technicians to ensure compliance with safety standards and optimal boiler performance․ Adhering to the manual prevents potential hazards and voiding warranties․ Only qualified professionals should use this guide, as improper procedures can lead to system malfunctions or safety risks․ Always refer to the manual before starting any installation or service tasks to guarantee efficiency and reliability․
Key Features of the Lochinvar Noble Combi Boiler
The Noble Combi Boiler offers high efficiency, a 10:1 turndown ratio, and 95% AFUE․ Its fire tube heat exchanger ensures reliable performance and energy savings, making it a top choice for residential heating needs․
2․1 High Efficiency and Condensing Technology
The Noble Combi Boiler features advanced condensing technology, achieving up to 95% AFUE, significantly reducing energy consumption․ This high-efficiency design captures heat from flue gases, ensuring maximum energy utilization and lower operational costs․ The boiler’s condensing process minimizes emissions, making it an environmentally friendly choice․ Proper installation and maintenance, as outlined in the manual, are crucial to sustaining its high performance and efficiency levels over time․
2․2 Fire Tube Heat Exchanger Design
The Noble Combi Boiler incorporates a fire tube heat exchanger, designed for optimal heat transfer and durability․ This compact design allows for efficient energy conversion while minimizing pressure drops․ The fire tube construction ensures even heat distribution and enhances the boiler’s reliability․ Its robust design resists thermal stress, making it a durable choice for both heating and domestic hot water needs․ This feature contributes to the boiler’s high efficiency and long-lasting performance;
2․3 10:1 Turndown Ratio and 95% AFUE
The Noble Combi Boiler features a 10:1 turndown ratio, enabling precise modulation to match heating demands․ This reduces cycling and enhances efficiency․ With an impressive 95% AFUE, the boiler maximizes energy conversion, minimizing fuel waste․ These advanced specifications ensure optimal performance, lower energy consumption, and higher reliability․ The combination of high turndown and efficiency makes the Noble Combi Boiler a cost-effective and environmentally friendly choice for residential heating and hot water needs․
Installation Recommendations
Follow the manual’s guidelines for proper piping, gas venting, and vent kit installation․ Use specified materials to ensure safe and optimal boiler performance․ Adhere to all safety protocols․
3․1 Proper Piping Methods
Proper piping is crucial for the Noble Combi Boiler’s efficiency and safety․ Use approved materials and sizing to ensure optimal flow rates․ Avoid leaks by securing connections tightly․ Follow local plumbing codes and manufacturer guidelines․ Proper pitch and routing prevent condensate buildup․ Use isolation valves for service access․ Ensure piping aligns with the boiler’s design specifications for maximum performance and longevity․ Adhere to these recommendations to maintain system integrity and efficiency․
3․2 Gas Venting Requirements
Proper gas venting is essential for safe and efficient operation of the Noble Combi Boiler․ Use only materials and methods specified in the manual to prevent hazards․ Ensure venting systems are designed to handle condensate and maintain proper airflow․ Install concentric vent kits for direct venting, and verify termination meets local codes․ Proper venting prevents carbon monoxide buildup and ensures optimal boiler performance․ Always follow manufacturer guidelines for venting configurations and materials to maintain safety and efficiency․
3․3 Concentric Vent Kit and Sidewall Vent Termination
The Noble Combi Boiler requires a concentric vent kit for proper gas venting through a sidewall․ Ensure the vent termination meets local codes and manufacturer guidelines․ The concentric vent kit simplifies installation and reduces the risk of condensate leaks․ Proper sealing and alignment are critical to maintain efficiency and safety․ Follow the manual’s instructions for vent kit assembly and termination to ensure compliance with safety standards and optimal boiler performance․ This configuration supports direct venting and reliable operation․
Service and Maintenance
Service and maintenance are crucial for optimal performance․ Always shut down the boiler, allow it to cool, and isolate it before servicing․ Regular cleaning and scale prevention ensure efficiency and longevity․
4․1 Shut Down and Cooling Procedures
To safely service the boiler, first shut it down using the power switch․ Allow the unit to cool to ambient temperature to avoid burns or damage․ Ensure all valves are closed and the boiler is isolated from the system․ This prevents residual heat or unintended operation․ Always follow the manual’s guidelines for proper shutdown and cooling procedures to maintain safety and system integrity during maintenance or repairs․
4․2 Isolation and Valve Closure
Before performing any maintenance, isolate the boiler from the system by closing all isolation valves․ Ensure the boiler is shut down and cooled․ Closing the valves prevents unintended operation and ensures safety․ Always refer to the manual for specific valve locations and procedures․ Proper isolation is critical to prevent system backflow and potential damage during service․ Follow the manual’s guidance for secure valve closure and isolation to maintain system integrity and safety during maintenance tasks․
4․3 Cleaning and Scale Prevention
Regular cleaning and scale prevention are essential for maintaining the Lochinvar Noble Combi Boiler’s efficiency and longevity․ Use approved cleaning products to remove debris and scale buildup, which can obstruct heat exchanger performance․ Clean the boiler annually or as needed, following the manual’s guidelines․ Scale prevention kits, like ScaleBreak-MP, can help mitigate lime scale accumulation․ Always ensure the system is cool and isolated before cleaning․ Proper maintenance prevents efficiency loss and potential damage, ensuring optimal boiler operation and reliability over time․
Technical Specifications
The Lochinvar Noble Combi Boiler offers a wide range of technical capabilities, including input and output BTU ranges, high-efficiency ratings, and advanced venting options for optimal performance․
5․1 Input and Output BTU Ranges
The Lochinvar Noble Combi Boiler models, such as the NKC110, NKC150, and NKC199, offer varying input and output BTU ranges to suit different residential needs․ With inputs ranging from 99,999 to 199,999 BTU/hr, these boilers provide flexible heating capabilities․ The high-efficiency design ensures an AFUE rating of 95%, maximizing energy savings․ Output BTUs are optimized for both space heating and domestic hot water production, making the Noble Combi a versatile choice for efficient home comfort systems․
5․2 Natural Gas Fuel Compatibility
The Lochinvar Noble Combi Boiler is designed to operate efficiently with natural gas, ensuring reliable performance and energy savings․ The boiler’s advanced combustion system is optimized for natural gas fuel, providing consistent heating and hot water delivery․ Proper installation and venting are crucial, as specified in the manual, to maintain safety and efficiency․ The Noble Combi Boiler’s compatibility with natural gas makes it a practical choice for homeowners seeking a high-efficiency, cost-effective heating solution․
5․3 Direct Vent and Water Connection Size
The Noble Combi Boiler requires a direct vent system using approved materials such as PVC, CPVC, or polypropylene․ The vent size must be a minimum of 2 inches for the concentric vent kit․ Water connections are typically 1-inch NPT, but may vary depending on the boiler model and installation requirements․ Proper sizing ensures efficient operation and prevents issues like backdrafting or reduced performance․ Always follow the manual’s specifications for precise measurements and compatible materials to maintain optimal efficiency and safety․
Troubleshooting Common Issues
This section provides solutions for common problems like the boiler not heating or low water cutoff․ Refer to the manual for detailed diagnostic guidance and resolutions․
6․1 Boiler Not Heating
If the Lochinvar Noble Combi Boiler fails to heat, check the gas supply and ensure the valve is open․ Verify that the boiler is properly powered and that all settings are correct․ If issues persist, inspect for blocked vents or faulty components․ Refer to the troubleshooting section in the manual for detailed guidance on diagnosing and resolving heating issues․ Always follow safety precautions when performing diagnostics or repairs․
6․2 Low Water Cutoff and Manual Reset
The low water cutoff is a critical safety feature that shuts off the boiler if water levels drop too low․ If activated, the boiler will not operate until manually reset․ To reset, ensure the system is cool, refill the water to the recommended level, and press the reset button located on the cutoff device․ Always verify proper water circulation before restarting the boiler․ If the issue persists, consult the manual or contact a qualified technician to address potential system imbalances or defects․
6․4 Condensate Neutralization
Condensate neutralization is essential to prevent corrosion in the boiler and piping system․ The Noble Combi Boiler requires a neutralization kit to treat acidic condensate․ Install the kit according to the manual’s specifications, ensuring proper flow and drainage․ Regularly inspect and maintain the kit to prevent blockages or inefficiencies․ Failure to neutralize condensate can lead to premature system damage․ Always follow the manufacturer’s guidelines for installation, maintenance, and replacement of neutralization components to ensure optimal boiler performance and longevity․